Radwin 5000 HPMP User Manual page 205

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Connecting an HSS Unit
the same mast as the ODUs. All collocated units connect to this box using CAT-5e cable.
Cables in prepared lengths are available for purchase.
The HSS unit is supplied with ten protective covers; any port not in use must be closed with a
protective cover.
Figure 10-4: HSS Interconnection Unit
Note
To connect an ODU to an HSS unit:
1. Unscrew the protective cover from the port marked SYNC 1.
2. Connect the RJ-45 connector from one end of the prepared CAT-5e cable to SYNC 1.
3. Connect the other end of the CAT-5e cable to the ODU connector labeled SYNC.
4. Tighten the protective seal that is on the prepared cable over the RJ-45 connector.
5. Repeat for all ODUs that are to be collocated at the hub site. The next ODU to be
connected is inserted in SYNC 1, SYNC 2, followed by SYNC 3 and so on.
RADWIN 5000 HPMP User Manual
For a single HSS unit, ensure that the collocated units are connected
in sequence from SYNC 1. If an ODU is removed from the hub site,
then all remaining ODUs must be reconnected to maintain the con-
nectivity.
You may cascade (daisy-chain) two or more HSS Units with an HSS
cable. The method is described in detail below.
Release 3.3.30