Radwin 5000 HPMP User Manual page 349

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Trap Parameters
Table C-3: MIB Traps (Sheet 2 of 6)
Name
hssOpStateChangedToINU
hssOpStateChangedToHSM
hssOpStateChangedToHSC
vlanModeActive
spectrumAnalysis
hbsHsuDeregisteredOffline
hbsHsuDeregisteredSuccessfully
hbsHsuRegisteredSuccessfully
hbsHsuRegistrationFailed
hbsHsuViolatedState
hsuViolatedState
hbsUnregisteredSynchronizedHsu
hbsUnregisteredUnsynchronizedHsu
cableQuality
httpAuthentication
telnetAuthentication
tdmServiceAlarm
ethServiceClosed
ethServiceNotPermitted
encryptionAlarm
changeLinkPasswordAlarm
externalAlarmInPort1Alarm
externalAlarmInPort2Alarm
bitFailedAlarm
wrongConfigurationLoadedAlarm
RADWIN 5000 HPMP User Manual
ID
Severity
Description
19
normal
Indicates that the HSS operating state was changed to INU type.
Contains a single parameter which is its description: 1 - Description:
HSS operating state was changed to: INU.
20
normal
Indicates that the HSS operating state was changed to HSM type.
Contains a single parameter which is its description: 1 - Description:
HSS operating state was changed to: HSM.
21
normal
Indicates that the HSS operating state was changed to HSC type.
Contains a single parameter which is its description: 1 - Description:
HSS operating state was changed to: HSC_DT/HSC_CT.
22
normal
Indicates to non-VLAN PC that after 2 minutes the system will support
only VLAN tag on management interface. Contains a single parameter
which is its description: 1 - Description: VLAN Mode is active. Non-VLAN
traffic will be blocked in 2 minutes.
23
normal
Indicates that the ODU is in Spectrum Analysis mode. Contains a single
parameter which is its description: 1 - Description: Spectrum analysis in
progress.
24
normal
Indicates that a HSU was deregistered offline (out of link)
25
normal
Indicates that a HSU was deregistered successfully
26
normal
Indicates that a HSU was registered successfully
27
normal
Indicates that registration has failed
28
normal
Indicates (on the HBS side) that a HSU is is violated state
29
normal
Indicates (on the HSU side) that the HSU is is violated state
30
normal
Indicates an unregistered HSU has been synchronized.
31
normal
Indicates an unregistered HSU lost synchronization.
32
normal
1Gbps rate is not supported due to bad line quality.
33
normal
HTTP Authentication Failure.
34
normal
Telnet Authentication Failure.
100
major
Indicates that TDM Service is in alarm state. Contains a single
parameter which is its description: 1 - Description: TDM Service - Alarm.
101
major
Indicates that Ethernet Service is closed. Contains a single parameter
which is its description: 1 - Description: Ethernet Service is closed.
102
major
Indicates that Ethernet Service is not permitted. Contains a single
parameter which is its description: 1 - Description: A valid IDU could not
be detected at %s. Please check your configuration. %s - Is the Local
Site name or Remote Site name or both sides of the Link.
103
major
Indicates an encryption key mismatch. Contains a single parameter
which is its description: 1 - Description: Encryption Status - Failed. No
Services are available.
104
major
Indicates that a failure has occurred while attempting to change the Link
Password. Contains a single parameter which is its description: 1 -
Description: Failed to change the Link Password at/on: %s. %s - Is the
Local Site name or Remote Site name or both sides of the Link.
105
major
The trap is sent every time an alarm occurs in the External Alarm Input of
port #1. Contains a single parameter which is its description: 1 -
Description: External Alarm 1 - <User Text> - Alarm.
106
major
The trap is sent every time an alarm occurs in the External Alarm Input of
port #2. Contains a single parameter which is its description: 1 -
Description: External Alarm 2 - <User Text> - Alarm.
107
major
The trap is sent if there is no way to recover from the situation.Contains
two parameters: 1 - Description: ODU power up built in test failed. Error
code is: %n 2 - %n number
108
major
The trap is sent if there is a way to recover from the situation.Contains
two parameters: 1 - Description: Wrong configuration loaded. Error code
is: %n 2 - %n number
Release 3.3.30
Appendix C
C-31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents