Configuring The Sector Out Of The Box - Ip Addresses - Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Configuring the Sector out of the Box - IP Addresses

Choose your unit locations carefully. For example, for three collocated HBSs
each with 32 HSUs covering 360°, matters get out of hand very quickly if
units are poorly named. They can always be identified by their IP
addresses, but that is a poor substitute for effective naming. A URL-like
naming pattern based on HBS_n.HSU_y is clear and familiar to all Internet
Tip
users. Keeping the names IP address independent enables you to copy the
entire sector setup to a different geographic location without IP address
duplication.
Configuring the Sector out of the Box - IP Addresses
The default log-on IP address for all ODUs in the sector is the same: 10.0.0.120, subnet mask
255.0.0.0 and default gateway 0.0.0.0. To get the process started, set up the IP address on
the network card on the managing computer to something like 10.0.0.100, subnet mask
255.255.255.0 and Default Gateway 0.0.0.0.
Ensure that you have a direct LAN connection to the HBS, run the RADWIN Manager and log-
on to it.
Figure 5-1: Logging on with factory default IP address
Alternatively, you can log on using Local Connection without need to change your Network
Interface Card address:
RADWIN 5000 HPMP User Manual
Release 3.3.30
Chapter 5
5-6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents