Additional Waterproofing for the Lightning Protection Unit and the Repeater
Figure 3-19: Exposing the tack side of the sealing tape
3. After connecting the short CAT-5 IDU/ODU cable (provided in the box) from the ODU
to the unit, tighten the cable gland cap firmly and use the insulation tape scotch 23
to fully cover both of the cable glands.
4. Connect the tape with tacky side up on the cable gland cap and the CAT-5 cable.
Start at Start Point at the bottom of the cable gland as shown in
ish at End Point of the CAT-5 cable, 2.5cm after the end of the shrink tubing.
Stretch the tape and apply half-overlapped to form gap-free joint.
Figure 3-20: Start and End points for protective-taping the unit
5. Wrap two layers of any scotch vinyl plastic electrical type (e.g Scotch Super 88 Vinyl
Plastic Tape from 3M) to protect the joints as shown in
RADWIN 5000 HPMP User Manual
Release 3.3.30
Figure
3-20. Fin-
Figure
3-21. Ensure that the
3-17