Trap Parameters
Table C-3: MIB Traps (Sheet 3 of 6)
Name
lanPort1DisconnectedAlarm
lanPort2DisconnectedAlarm
mngPortDisconnectedAlarm
externalAlarmInPort3Alarm
externalAlarmInPort4Alarm
swVersionsMismatchFullCompatibilityAlarm
swVersionsMismatchRestrictedCompatibilityAlarm
swVersionsMismatchSoftwareUpgradeRequired
swVersionsIncompatible
hssMultipleSourcesDetectedAlarm
hssSyncToProperSourceStoppedAlarm
hssSyncPulseDetectedAlarm
tdmBackupAlarm
linkLockUnauthorizedRemoteODU
linkLockUnauthorizedODU
hotStandbyAlarm
sfpInsertion
sfpPort1DisconnectedAlarm
ringRplStateActiveAlarm
desiredRatioCanNotBeAppliedAlarm
RADWIN 5000 HPMP User Manual
ID
Severity
Description
109
major
Indicates the LAN port 1 status changed to disconnected.Contains a
single parameter which is its description: 1 - Description: LAN port 1
status changed to disconnected.
110
major
Indicates the LAN port 2 status changed to disconnected.Contains a
single parameter which is its description: 1 - Description: LAN port 2
status changed to disconnected.
111
major
Indicates the management port status changed to disconnected.Contains
a single parameter which is its description: 1 - Description: Management
port status changed to disconnected.
112
major
The trap is sent every time an alarm occurs in the External Alarm Input of
port #3. Contains a single parameter which is its description: 1 -
Description: External Alarm 3 - <User Text> - Alarm.
113
major
The trap is sent every time an alarm occurs in the External Alarm Input of
port #4. Contains a single parameter which is its description: 1 -
Description: External Alarm 4 - <User Text> - Alarm.
114
warning
The trap is sent if SW versions mismatch with full link functionality.
Contains a single parameter which is its description: 1 - Description:
Software versions mismatch - full link functionality
115
minor
The trap is sent if SW versions mismatch with restricted link functionality.
Contains a single parameter which is its description: 1 - Description:
Software versions mismatch - restricted link functionality
116
major
The trap is sent if SW versions mismatch and SW upgrade is required.
Contains a single parameter which is its description: 1 - Description:
Software versions mismatch - Software upgrade required
117
critical
The trap is sent if SW versions are incompatible. Contains a single
parameter which is its description: 1 - Description: SW Versions
incompatible
118
major
Indicates that multiple sync pulse sources were detected. Contains a
single parameter which is its description: 1 - Description: HSS multiple
sync sources were detected.
119
major
Indicates that synchronization to a proper sync pulse source was
stopped. Contains a single parameter which is its description: 1 -
Description: HSS sync pulse - Down. The reason is: %s. %s - Is the
reason for the sync down.
120
major
Indicates that HSS additional sync pulse was detected. Contains a
single parameter which is its description: 1 - Description: HSS additional
sync pulse was detected.
121
major
Indicates that the TDM backup link was activated. Contains a single
parameter which is its description: 1 - Description: TDM backup alarm -
backup link was activated.
122
major
Indicates that the remote ODU is unauthorized.
parameter which is its description: 1 - Description: Unauthorized remote
ODU connection rejected.
123
major
Indicates that the ODU is unauthorized.
which is its description: 1 - Description: Unauthorized ODU connection
rejected.
124
major
Indicates that the hot standby secondary link was activated. Contains a
single parameter which is its description: 1 - Description: Secondary
Link Is Active.
126
normal
Indicates that a device was inserted to SFP Port
127
major
Indicates the SFP port 1 status changed to disconnected.Contains a
single parameter which is its description: 1 - Description: SFP port 1
status changed to disconnected.
128
major
RPL state changed to Active.
129
normal
Indicates Desired UL/DL RAtio Can Not Be Applied.
Release 3.3.30
Appendix C
Contains a single
Contains a single parameter