Figure 10-12 Hbs As - Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Sector Configuration and HSS
If you select Hub Sync Master and click Apply, the display changes again:
Figure 10-12: HBS as HSM
The possible External Pulses conditions are shown in the following table:
Table 10-6: External Pulse Status
HSS Sync Status
Generating
Detected
Not detected
Generating and detected
Generating and
Improperly Detected
Not detected
Improperly detected
RADWIN 5000 HPMP User Manual
Meaning
ODU is HSM and generates the
sync pulse
ODU is HSC and detects the
sync pulse
ODU is independent
HSM, but other HSM present
RADWIN 5000 HBS is HSM, but
detects a WinLink 1000 or
RRADWIN 2000 HSM signal
that is not RFP E
HSC but no HSM present
HSC but HSM pulse doesn't fit
the HSC as configured. Occurs
only for RADWIN 5000 HBS,
which stops transmitting.
Release 3.3.30
Color code
Green
Orange
Red
Chapter 10
10-10

Hide quick links: