The threshold value is the power ratio in decibels (dB) of the measured
◆
power referenced to one milliwatt (mW).
Refer to the Command Usage section under the
◆
current
thresholds.
Trap messages configured by this command are sent to any
◆
management station configured by the
E
XAMPLE
The following example sets alarm thresholds for the signal power received
at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold rx-power low-alarm 9
Console(config-if)#transceiver-threshold rx-power high-alarm 99
Console#
This command sends a trap when the transceiver temperature falls outside
transceiver-
of the specified thresholds.
threshold
temperature
S
YNTAX
transceiver-threshold temperature {high-alarm | high-warning
| low-alarm | low-warning} threshold-value
high-alarm – Sends an alarm message when the high temperature
threshold is crossed.
high-warning – Sends a warning message when the high
temperature threshold is crossed.
low-alarm – Sends an alarm message when the low temperature
threshold is crossed.
low-warning – Sends a warning message when the low
temperature threshold is crossed.
threshold-value – The threshold of the transceiver temperature.
(Range: -20000 - 20000 in units of 0.01 Celsius)
D
EFAULT
None
S
ETTING
M
ODE
U
SAGE
command for more information on configuring transceiver
S
ETTING
– 829 –
| Interface Commands
C
28
HAPTER
transceiver-threshold
snmp-server host
command.