Definitions - prime mover smx45 Master Service Manual

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

© BT Prime-Mover, Inc.
Return
Pin number 1 is located in the back row right side when
viewing the logic connector.
Pin No
P1
CAN High
P2
IN/OUT Lower Valve
P3
Not Used
P4
Out Main Contactor
P5
IN/OUT Brake
P6
OUT Pump Contactor
P7
OUT Horn
P8
CAN Low
P9
Not Used
P10
Not Used
P11
Not Used
P12
IN Arm Angle A
P13
Not Used
P14
IN Arm Angle B
P15
IN Lift Limit
P16
IN +24 VDC

1.6. Definitions

Overtemperature.
controller is from 185 degrees F (85 degrees C) and above.
Overheating is unusual, but can occur if the transistor
controller
is
installed
overtemperature the drive current limit is linearly decreased
from full set current down to zero. Plug current is not reduced
by any thermal conditions to allow full plugging strength at all
times.
Undertemperature. When the transistor controller is
operating at less than −13 degrees F (−25 degrees C), the
current limit is cut back resulting in reduced travel speed and
acceleration.
Pulse Width Modulation. Pulse Width Modulation (PWM),
also called "chopping," controls the speed of the motor by
switching the battery voltage to the motor on and off very
quickly.
Master Service Manual
2006-12-12
F-code
Section
PT
S5.7
Transistor Controller
Version no
T-code
001
SMX
Connecting
Overtemperature
of
incorrectly
or
C-code
5460
the
transistor
overloaded.
At
243

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents