Troubleshooting; Repair And Rebuild - prime mover smx45 Master Service Manual

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

F-code
Section
PT
S5.2
Swing Out Battery Pack
Version no
T-code
002
SMX
210
Return
C-code
5110
b. Excessive
c. Bad battery or poor DC connection.

3. Troubleshooting

The charger incorporates a very simple and reliable design
which makes troubleshooting relatively easy. The repair
procedure involves testing the output of the charger and then
testing individual components. The test procedures follow a
logical sequence of electrical flow through the circuit. Only
standard hand tools and an AC/DC volt/ohm meter are
required. A battery hydrometer is recommended.
WARNING

4. Repair and Rebuild

Contact your local battery supplier for replacements or
rebuilds.
Master Service Manual
that it is comparable to the original batteries.
Automotive type batteries will not function
properly in this application.
battery
suppressed battery voltage.
Allow batteries to cool.
Check battery voltage while charger rate is
controlled by the battery state of charge. This
will adjust the output to the proper level if the
battery is in good condition. If the voltage does
not come up to finish rate, this may indicate a
bad cell within a battery or a marginal DC
connection between the battery and the
charger. Carefully inspect connections for
excessive heat. Test battery cell voltages and
specific gravity.
Before checking charger, disconnect AC
power
supply,
unplug
discharge capacitor with an insulated
screwdriver. All tests should be made with
extreme caution when a test calls for power
to be "on" at the charger.
temperatures
causing
batteries,
and
2006-08-08

Hide quick links:

Advertisement

Table of Contents
loading