Main On/Off Switch/Keypad On - prime mover smx45 Master Service Manual

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

F-code
Section
PT
S5.0
Electrical Functions
Version no
T-code
002
SMX
Pressure Oil
Return Oil
B+ Circuit
B- Circuit
Signal
Pre-Charge Voltage
148
Return
C-code
5000

1.3. Main ON/OFF Switch/Keypad ON

When the switches on wire number 22 connects to the battery
voltage to the ETAC (A2) pin J11-1, this powers up the ETAC
(A2) for start of communication to the transistor controller
(A1). A voltage of volts from the resistor (PTC R1) 1.0 to 1.5
volts less than battery voltage is provided to the positive side
of arm angle A switch (S24), arm angle B switch (S25), and
the normally closed lift limit switch (S36) to the transistor
controller (A1) pin J5-15.
Symbol
A1
Drive Transistor Controller
A2
Electronic Tiller Arm Card Transistor Controller
F50
Keypad/Tiller Arm Circuit Fuse
F51
Main Control Fuse
H1
Horn
J11
Handle Stem Base Wire Connection
J41
Service Key (CAN) Wire Connection
K4
Main Contactor Relay
K10
Main Contactor
K30
Pump Motor Solenoid
Master Service Manual
Designation
Symbol
M1
M3
S18-1
S18-2
S21
S24
S25
S36
Y1
Y10
Designation
Drive Motor
Pump Motor
Horn Switch
Horn Switch
Main ON/OFF Switch
Arm Angle (A) Switch
Arm Angle (B) Switch
Lift Limit Switch
Brake Coil
Lower Valve Coil
2006-12-12