prime mover smx45 Master Service Manual page 175

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

Parameters 1-7 are Driver Parameters (7 parameters for each Drive PIN code entered
Parameter
1
Max speed, slow mode
2
Max speed, fast mode
3
Acceleration
4
Deceleration
5
Truck off delay (keypad
only)
© BT Prime-Mover, Inc.
Return
The parameter change is complete. The next time the truck is
started, the new parameter will be in effect.
Truck Parameters
Name
Unit
Range
%
10 to 40
%
70 to 98
%
30 to 90
%
40 to 90
min
All parameters can be viewed, however, not
all parameters can be changed. Truck
NOTE!
parameters may or may not be accessed,
depending on the value of parameter 39
(see
page
Step Default
2
20
2
94
5
80
5
65
0 to 20
1
0
Master Service Manual
2006-12-12
F-code
Section
PT
S5.0
Electrical Functions
Version no
T-code
002
SMX
179.)
Description
Maximum speed value sent to transistor
controller while in Slow, except during Turtle
Torque (gives torque boost if high load
encountered.)
Reduces speed value sent to transistor
controller while in Fast (all throttle positions.)
Defines truck's acceleration characteristic,
lower
number
gives
less
acceleration.
Defines
truck's
automatic
characteristic when throttle is reduced
(including to neutral); lower number gives
less aggressive acceleration
Sets truck off delay (energy saving feature);
if truck is not used for this amount of time,
the ETAC powers the truck off. When this
parameter is set to 0, the truck never
powers off. If parameter 39 is 1 or 2 (truck
has key switch option), the truck never
powers off.
C-code
5000
aggressive
plug-braking
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents