Code E108 - Contactor Welded or Missing
Main contactor tips welded or missing.
1.
Main contactor tips welded.
2.
Open or short circuit in contactor circuit.
a.
Check contactor, wiring (coil) and cabling.
3.
Bad transistor controller.
4.
Low voltage.
a.
Try closing contactor with a known-good battery.
5.
Blown drive fuse.
Code E110 - Braking System Fault
Transistor controller detected problem with braking functions.
1.
Short circuit in brake circuit.
a.
Check brake and wiring.
2.
Bad transistor controller.
Code E112 - Arm Angle Sequence Fault
Improper sequence of arm angle inputs.
1.
Arm angle input stuck on or off.
2.
Problem with arm angle input wiring.
3.
Problem with arm.
a.
Check for proper sequence of arm angle switches (see step 2 above.)
Code E114 - Traction (Drive) Motor Speed Fault
Transistor controller detected stalled traction motor.
1.
Traction motor stalled.
2.
Excessive traction motor load at low speed.
a.
Check brake adjustment (see
3.
Bad transistor controller.
Code E140 - Checksum Error
Electronic Tiller Arm Card (ETAC) software detected that checksum was invalid.
1.
Bad software.
a.
If applicable, try downloading new software.
2.
Bad ETAC.
Code E141 - Software Problem
ETAC found problem with software.
1.
Bad software.
a.
If applicable, try downloading new software.
2.
Bad ETAC.