prime mover smx45 Master Service Manual page 179

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

© BT Prime-Mover, Inc.
Return
• With the battery connected to the truck, service key
connected, main ON/OFF switch turned to the ON
position, press and hold down the horn button.
• Enter key code and press "I" or turn on key switch.
• The display will now show: H - Hour meter, E - Error
Codes, P - Parameters, and Pn - Software number.
These symbols will cycle continuously until the horn
button is released.
• Release the horn button when the display shows "P"
(if the horn button is released at the wrong time, turn
off the truck and start over.)
• The parameter symbol below the display lights up;.
• The value of parameter # 1 is shown on the display
(although parameter # 1 is not functional at this time.)
• Use the thumb controls to scroll to the desired
parameter.
When the thumb control is rotated slightly, the display
changes to show the parameter number currently
active. Rotating the thumb control further increments
the parameter up or down according to which
direction the control is rotated.
• Release the thumb control to neutral when the desired
parameter
number
programmed value of that parameter is now shown on
the display.)
• Press the horn button once to make the parameter
value displayed start to flash.
• Rotate the thumb control to increment the parameter
value up or down, depending upon the direction the
control is rotated.
• Release the thumb control to neutral when the desired
parameter value is displayed.
• Press the horn button once to lock in the new
parameter value and verify this parameter has quit
flashing.
• Turn off truck when programming is completed.
Master Service Manual
2006-12-12
F-code
Section
PT
S5.0
Electrical Functions
Version no
T-code
002
SMX
is
shown.
(The
C-code
5000
current
177

Hide quick links: