NOTE!
If the AC power fuse blows or the DC 1 x
circuit breaker trips, check for reverse
polarity of the battery connection.
a. Open circuit voltage test.
With batteries disconnected and the charger
turned on, the DC output voltage should be
1-1/2 times the rated DC voltage.
b. Short circuit amperage test.
With charger output battery connector short
circuited (positive to negative jumper connector
plugged into charger output connector), and the
charger turned on, the DC output amps should
be 80 percent of the normal DC amps.
System voltage
24 volts
(1) With charger in the OFF position, connect
(2) Turn battery charger on and note the amp
(3) Turn charger off before disconnecting the
4. Testing components
Master Service Manual
2006-08-08
F-code
PT
Swing Out Battery Pack
Version no
002
System voltage
24 volts
Short circuit output voltage
approximate 12 amps
AC power cord to appropriate AC power
supply, connect with the + to - loop to the
charger.
gauge reading. It should be as stated on the
chart above. Leave charger on for five
minutes while watching the amp gauge.
The amp gauge should remain steady. This
verifies the condition of the circuit breaker
and any loose connections.
jumper connector.
Section
C-code
S5.2
5110
T-code
SMX
207