Circuit Breaker - prime mover smx45 Master Service Manual

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

F-code
Section
PT
S5.5
Fuses/Circuit Breakers
Version no
T-code
001
SMX
232
Return
C-code
5390

2.3. Circuit Breaker

Under extreme operating conditions, the current demand on
the battery may exceed the rating for the main circuit breaker
(CB1) and force it open. This causes the truck to become
inoperable until the circuit breaker automatically resets itself.
To test a circuit breaker, remove the circuit breaker from the
truck or isolate it from the electrical circuit by removing all the
connections from one side. Let it cool (or reset itself.) Use an
ohmmeter set to Rx1 scale and measure the resistance
across the circuit breaker. The resistance must be less than 1
ohm.