prime mover smx45 Master Service Manual page 208

Electric walkie low-lift pallet truck
Hide thumbs Also See for smx45:
Table of Contents

Advertisement

F-code
Section
PT
S5.2
Swing Out Battery Pack
Version no
T-code
002
SMX
206
Return
C-code
5110
b. Volts per cell, open circuit, before and after
c. Charging rate DC amps, at start and finish of
Acceptable values
24 volt system
d. Charging rate at battery DC volts, at start and
Acceptable values
24 volt system
2. Visually
disconnected.
a. Inspect AC power supply circuit breaker, wall,
b. Inspect charger for physical damage.
c. Inspect internally for loose or discolored
d. Inspect
e. Inspect the charger's internal AC power fuse. It
NOTE!
3. Testing the DC output circuit.
Master Service Manual
Any cell that is different by more then 20 points
indicates a suspect battery.
charging.
Acceptable values:
Dead battery - 1.9 v/cell
Fully charged - 2.2 v/cell
charge cycle.
Start
15 amps
finish.
Start
25.6 volts
inspect
charger
outlet, plug, cord.
connections and wires damaged due to
overheating.
transformer
discrepancies.
should be 10 amp rated.
If the AC power fuse is blown, it could
indicate a shorted diode on the DC output
circuit.
Finish at 2.5 VPC
0.5 amps or less
Finish
30.0 volts
with
all
power
coils
for
obvious
2006-08-08