2
Disconnect the Scan Cable
1
Disconnect the Flat
Cable
Figure 2 Removing the Scan Cable
Replacement
1.
Reinstall the parts in the reverse order of disassembly.
Electronic Pre-Collation (EPC)
REP 20.3, REP 20.4
REP 20.4 EPC Print Cable
Parts List on
PL 20.1
Removal
1.
For DCCS50:
Switch Off the power. Wait 30 seconds, then unplug the power cord. Disconnect the
IDFE DDI Cables.
For DC12 with attached Fiery or Splash DFE:
Perform the correct power down procedure. Disconnect the DFE DDI cables.
For DC12 without an attached DFE:
Switch off the power and disconnect the power cord.
2.
Undock the Finisher or Mailbox/Sorter, if present.
3.
Remove the following:
Exit Tray
(PL
12.11)
Right Upper Cover
4.
Remove the Print Cable
Disconnect the
Connector
Figure 1 Removing the Print Cable
Replacement
1.
Reinstall the parts in the reverse order of disassembly.
1/05