Unswitched AC Power

Principles of Operation
Unswitched AC Power
As shown in
Figure
routed through the GFI Circuit Breaker and the Noise Filter. The Noise Filter prevents
unwanted signals from entering the machine on the power line. The Noise Filter Output is pro-
vided to the 18 VAC Transformer and to the Choke Coil. The Choke Coil is another type of
noise filter and supplies the IDFE LVPS. The output of the 18 VAC Transformer goes back to
the AC Driver PWBA.
Power.
Figure 1 Unswitched AC Power Routing
1/05
10-12
manuals4you.com
manuals4you.com
1, unswitched Prime AC Power enters the machine and is immediately
Figure 2
shows the locations of the assemblies used for Unswitched AC
Reissue