Table 1 Photoreceptor Motor Control Lines and Condition
On Gain 1 Gain 2 CLK
Brake
0
X
X
N/A
X
1
0
0
544.0 Hz
1
1
0
1
N/A
1
1
1
0
1179.4 Hz
1
1
1
1
1996.0 Hz
1
0
The Photoreceptor Motor drives the Photoreceptor Drum and the IBT Drive Roll.
Reissue
DocuColor 12/DCCS50
Figure 1 Photoreceptor Motor Control Circuit
ENC A
Main Motor Operating Condition
0 Hz
Motor Off
544.0
59.82 mm/sec process speed
Not used
1179.4
129.68 mm/sec process speed
1996.0
219.47 mm/sec process speed
0 Hz
Locked
1/05
10-53
Principles of Operation
Drum Motor