7) Loosen the fixing nut [1] of the scanner by turning
the spanner (large) [2] in the direction of [A].
[2]
When loosening the caster fixing nut [1] on the front
of the saddle finisher, be sure to fit the spanner [3]
through the gap below the saddle assembly base
plate [2].
[3]
8) Turn the adjusting bolt [1] with a spanner (small)
[2]. Adjusting the height measured at step 6) so
that it becomes 84.6 +/-0.5 mm.
- to raise, turn in the direction of [A].
- to lower, turn in the direction of [B].
(A single full turn causes a change of about 1.75
mm.)
[1]
[A]
F-5-8
[2]
F-5-9
[2]
9) Tighten the fixing nut [1] in the direction of [B].
[1]
10) Likewise, adjust the remaining 3 casters.
11) Connect the finisher to the host machine, and
check the height.
If the difference is +/-2 mm, mount the removed
parts such as the cover. Otherwise, repeat the
adjustment procedure.
Chapter 5
[A]
[B]
F-5-10
[B]
F-5-11
[1]
[1]
5-5