VISTA-32FB Installation and Set-Up Guide

Mounting the VIP Module

The VIP Module may be mounted in the control cabinet if space is available or, if this is not
possible, on the side of the cabinet or adjacent to it. Pry off the VIP Module's cover before
wiring.
1. When the VIP Module is mounted inside the control cabinet, attach it to the cabinet's
interior surface with 2-faced adhesive tape. The module's cover may be left off if it is
mounted within the cabinet.
Do not mount the VIP Module on the cabinet door or attempt to attach it to the PC board.
2. When the module is to be mounted outside the cabinet, use the screw holes at the rear to
mount horizontally or vertically (2-faced adhesive tape may be used, if preferred). The
wires can be brought out from the side or back of the cabinet (a round breakout is also
available on the back). When the mounting and wiring of the module is complete, the
module's cover can be attached (with label affixed, as indicated next).
3. Affix the 4285/4286 connections label (supplied separately) to the inside of the VIP
Module's cover, if the cover is used. Otherwise, affix the label to the inside of the control
cabinet's door.

Wiring the VIP Module

The 4285/4286 is wired between the control panel and the premises' handset(s) (see Figure
10-1). It listens for touch-tones on the phone line and reports them to the control panel.
During on-premises phone access, it powers the premises' phones; during off-premises phone
access, it seizes the line from the premises' phones and any answering machines.
1. Make 12V (+) and (–) and data-in and data-out connections from the VIP Module to the
control using the connector cable supplied with the VIP Module. These are the same
connections as for remote keypads.
2. Insert the keyed connector at the other end into the mating header on the VIP Module.
3. Connect terminals 1 through 7 on the VIP Module as shown.
4285/4286 Terminal
1. Phone In (Tip)
2. Phone In (Ring)
3. Phone Out (Tip)
4. Phone Out (Ring)
5. No Connection
6. Audio Out 1*
7. Audio Out 2*
*Supported by the 4286 only
Use an RJ31X Jack with the phone cable supplied with the control. Use an additional RJ31X
Jack and a direct-connect cord to make connections to the 4285/4286.
10–2
Terminal Block Connections
Connects to:
green wire of direct-connect cord
red wire of direct-connect cord
brown wire of direct-connect cord
gray wire of direct-connect cord
Speaker
Speaker

Hide quick links: