Global Arming

If enabled for the user, the keypad will display the following:
ARM ALL
0 = NO , 1 = YES
Notes:
When using the Global Arm feature, if there are faults in any of the selected partitions,
the system will enter a Summary Mode in which the faulted zones of all of the selected
partitions will be displayed. These faults must be corrected or bypassed ([Code] +
[BYPASS] + [#] will attempt to bypass the faults in all of the selected partitions). This
Summary Mode will end in approximately 120 seconds if no keys are pressed.
If, when disarming the system using a Global Disarm, any of the selected partitions has
a condition that would cause the keypad to beep (such as alarm memory or a trouble
condition), the system enters a Summary Mode. While in this mode, the alarm memory
or trouble conditions of all of the selected partitions will be displayed. Summary mode
will continue until either approximately 120 seconds elapses or a second disarm occurs
that clears the beeping.

Access Control

The system has the capability to utilize an access control relay in each partition. The relay
must be enabled in Relay Programming and programmed in data field 1 76.
To activate this relay, the user enters [User Code] + [0]. The relay will pulse for two
seconds.

Delaying Closing Time

If open/close schedules are used, end users can manually delay closing time by extending the
closing window by 1 or 2 hours. This is useful if a user must stay on the premises later than
usual. The user must have an authority level of Manager or higher.
To extend the closing window, enter [User code] + [#82].
Closing Delay ?
Hit 0-2 Hours
An extension of the closing window cannot be reduced once it is set. However, a 1-hour delay can
be increased to 2 hours. This is to prevent the user from deleting the delay after the normal
window expires, thereby missing the end of the window.
If NO, the keypad prompts for arming each partition
?
individually. If YES, the system attempts to arm all partitions
allowed by this user. If there are any faults (open doors,
windows, etc.) the keypad will display them. See notes below.
These faults must be corrected or the zone bypassed before
arming will occur. When faults are corrected, repeat the arming
procedure.
Enter the number of hours, 1 or 2, by which the end of the
closing window should be extended. Note that the delay is from
the scheduled closing time, not from the current time.
Press [ ] to accept entry and exit this mode. Press [#] to exit
this mode without changes.
The system will send an Access Schedule Change report to the
central station when the closing window is extended (if
programmed).