ADEMCO VISTA-32FB Installation And Setup Manual page 125

Fire and burglary partitioned security system with scheduling
Table of Contents

Advertisement

49 CHECKSUM VERIFICATION
Enter 1 for either or both primary/secondary formats to send a verification digit to
validate the message at the receiver without having to send two message rounds.
Selection is valid for 3+1, 4+1, and 4+2 reports.
Enter 0 if not desired.
50 SESCOA/RADIONICS SELECT
Enter 0 if Radionics format is to be used with hexadecimal 0-9, B-F reporting. Enter 1 if
Sescoa format is to be used with only numeric reporting (0-9). Note that selection
applies to both primary and secondary phone numbers.
51 DUAL REPORTING
This field allows all reports to be sent to both primary and secondary phone numbers.
Enter 1 if all reports are to be sent to both primary and secondary phone numbers. If
used with Split Reporting option 1 (1 34), Alarms go to both primary and secondary
numbers, while all other reports go to secondary only. If used with Split Reporting
option 2, alarms go to both lines, Open/Close and Test messages go to secondary only,
while all other reports go to primary. If used with Split Reporting option 3, Fire Alarms
and Supervisory reports go to primary, all reports go to secondary. Enter 0 if Dual
Reporting is not desired.
52 STANDARD/EXPANDED REPORT PRIMARY
Alm
Rst
Byp
Enter 0 for standard or 1 for expanded reporting for the primary phone number; default
is 0.
Note: Expanded overrides 4+2 format.
53 STANDARD/EXPANDED REPORT SECONDARY
Alm
Rst
Byp
Enter 0 for standard or 1 for expanded reporting for the secondary phone number;
default is 0.
Note: Expanded overrides 4+2 format.
56 USE ONLY LRR (LONG RANGE RADIO)
Enter 1 if the built-in dialer is not being used and only the LRR will be used to
communicate. Otherwise enter 0.
57 USE LRR (LONG RANGE RADIO) IF DIALER FAILS
Enter 1 if LRR is to be used as a backup to the built-in dialer if the dialer fails. The
radio messages begin transmitting the same time as the dialer. Once the dialer receives
a kissoff, the LRR will stop transmitting no matter where it might be within its
sequence. Otherwise enter 0.
Trbl
Opn/Cls Low Batt
Trbl
Opn/Cls Low Batt
Section 23 – Data Field Descriptions
[0,0]
[0]
[0]
[0]
[0]
23–7

Hide quick links:

Advertisement

Table of Contents
loading