Battery Supervision - ADEMCO VISTA-32FB Installation And Setup Manual

Fire and burglary partitioned security system with scheduling
Table of Contents

Advertisement

It is recommended that all batteries be replaced at the same time, even if only one
battery has become weak.
4. Attach the Red and Black wires on the battery connector as follows:
a) Red to positive (+) battery tab on the control board.
b) Black to the negative (-) battery tab on the control board.
5. Attach the Red and Black wires at the other end of the battery connector cable as follows:
a) Red to positive (+) terminal on the battery.
b) Black to the negative (-) terminal on the battery.

Battery Supervision

The VISTA-32FB runs a brief battery test once a minute to determine if battery leads are
connected, and runs an extended battery test every 24 hours to determine if battery capacity
is low (less than approximately 11.5VDC). If a low battery condition exists, it will be
displayed at the control's keypad(s). The indication will stop when the low battery condition
has been restored to normal (for several minutes). Refer to Section 30: Testing The System
for additional battery test information.Powering Up the System
Use batteries with approximately the same age and state of charge.
Use cables provided and observe polarity.
(See the Summary Of Connections diagram for location of the (+) and (-) battery tabs
on the control board.)
Section 19 – Final Power-Up Procedure
19–7