Time-Driven Events - ADEMCO VISTA-32FB Installation And Setup Manual

Fire and burglary partitioned security system with scheduling
Table of Contents

Advertisement

Quit ?
1 = YES 0 = NO 0

Time-Driven Events

These are the schedules used to activate outputs, bypass zones, etc. based on a time
schedule. There are 20 of these events that may be programmed for the system, with each
event governed by the previously defined time windows.
The actions that can be programmed to automatically activate at set times are: relay
commands, arm/disarm commands, zone bypassing commands, and open/close access
conditions.
Time-Driven Events Worksheet
Fill out the worksheet using the steps outlined below.
Sched
Num.
1
2
3...20
1) First enter the schedule number (01-20) and time window number (01-20), and
note the day of the week the action is desired.
2) Enter the code for the desired action and action specifier. The action codes are the
events that are to take place when the scheduled time is reached. Each action also
requires an action specifier, which defines what the action will affect (relay, relay group,
partition, zone list, user group). The action specifier varies, depending on the type of
action selected.
The following is a list of the Action Codes (desired actions) used when programming time-
driven events. Note that these codes are independent of the relay codes programmed
during Relay Programming in #93 Menu Mode (refer to the Quick Start Guide).
Relay commands
The HOLIDAY NUMBER? prompt will be displayed again.
Repeat the procedure for each holiday to be programmed.
Enter 0 at the QUIT ? prompt to return to the main menu
choices and continue programming.
Enter 1 to quit Scheduling Menu Mode.
Time
Days
Window M T W T F S S H Desired
Action Code
01 Relay On
02 Relay Off
03 Relay Close for 2 seconds
04 Relay Close XX minutes (set in field 1 74)
05 Relay Close YY seconds (set in field 1 75)
06 Relay Group On
07 Relay Group Off
08 Relay Group Close for 2 seconds
09 Relay Group Close XX minutes (set in field 1 74) Relay Group #
10 Relay Group Close YY seconds (set in field 1 75) Relay Group #
Section 24 – Scheduling Options
Action
Action
Specifier
Action Specifier
Relay #
Relay #
Relay #
Relay #
Relay #
Relay Group #
Relay Group #
Relay Group #
Activation
Time
24–11