The #80 Scheduling Menu Mode is used to program most of the scheduling and timed-event
options. To enter this mode, the system must first be in the normal operating mode (all
partitions disarmed). Enter [Installer Code] + [#] + [80].
The following can be programmed while in this mode:
Define time windows.
Assign open/close schedules to each partition.
Assign holiday schedules.
Program time-driven events (for system functions and relay activation).
Assign limitation of access schedules.
Some scheduling features are programmed in Data Field Programming Mode ([Installer
Code] + [8 0 0]). The general Programming Mode scheduling fields are listed below.
System-Wide Fields:
Partition-Specific fields:
Report Code Programming in #93 Menu Mode (refer to the Quick Start Guide)
Event-driven relay activation options are programmed using Relay Programming in # 93
Menu Mode (refer to the Quick Start Guide). These actions are in response to a
programmed action. However, relay activation can also be time-driven, and thus be used to
initiate a desired action. Time-driven relay activation options are programmed using #80
Menu Mode. Refer to Time-Driven Event Programming later in this section for procedures.
Steps To Programming Scheduling Options
This section contains examples of the worksheets only. For complete worksheets, see the Quick
Start guide accompanying these Installation Instructions.
In order to use #80 Scheduling Menu Mode, do the following:
Using the worksheets:
Define time windows (up to 20).
Define the daily open/close schedules (one schedule per day, per partition).
Define the holidays to be used by the system (up to 16).
Define limitation of access times (up to 8 schedules).
Define the time-driven events (up to 20).
Note: Temporary schedules are programmed using #81 Menu Mode.
24–6
1 74 -1 75 Relay timeout values
2 01-2 02 Daylight savings time options
2 11
1 76
2 05
2 06
2 07
2 08
2 09
2 10
(System Group #3)
Allow disarming outside window if alarm occurs
Access control relay for this partition
Auto-arm delay value
Auto-arm warning time
Auto-disarm delay value
Force-arm enable
Open/Close Reporting by Exception
Restrict disarm only during windows
Scheduling related report codes