35 DOWNLOAD PHONE NUMBER
This field is applicable only if downloading will be utilized.
Enter the downloading phone number, up to 17 digits, 0-9; enter #11 for , #12 for #,
and #13 for a 2-sec. pause. Do not fill unused spaces.
36 DOWNLOAD ID NUMBER
|
Enter eight digits, 00-09; A-F (10-15). Default is [15, 15, 15, 15, 15, 15, 15, 15]. Only
applicable if downloading will be utilized. Make entries as 2-digit numbers as follows:
00=0 02=2 04=4 06=6 08=8 10=A 12=C 14=E
01=1 03=3 05=5 07=7 09=9 11=B 13=D 15=F
37 DOWNLOAD COMMAND ENABLES
Dialer
System
Shutdown
Shutdown
Each of the various remote functions can either be enabled or disabled through the
keypad for usage by Compass downloading software. Disabling a function means that
you will not be able to perform that function from Compass.
Enter 1 to enable a function, and 0 to disable a function. See field 1*53 to disable the
Download Callback option.
installations, all entries must be 0. Default is [11011111].
38 PREVENT ZONE XXX BYPASS (partition-specific)
Entering a zone number (001-032) prevents that zone from being bypassed by the user.
Enter 000 if this feature is not desired (all zones can be bypassed).
39 ENABLE OPEN/CLOSE REPORT FOR INSTALLER CODE (partition-specific)
Enter 1 if Open/Close reporting for the installer is desired.
Otherwise enter 0.
40 OPEN/CLOSE REPORTING FOR KEYSWITCH
Enter 1 to enable Open/Close reporting for the keyswitch.
Enter 0 if reporting is not desired.
41 NORMALLY CLOSED OR EOLR (ZONES 3-8)
Enter 0 if end-of-line resistors are to be used.
Enter 1 if end-of-line resistors are not to be used, in which case only normally closed
devices must be used.
Must be 0 for commercial fire and UL installations.
| | | | | | | | | | | | | | | |
|
|
Not
Remote
Remote
Used
Bypass
Disarm
For commercial fire and UL commercial burglary
Section 23 – Data Field Descriptions
|
|
|
Remote
Upload
Arm
Program
|
|
Download
Program
[000]
|
|
[1]
[0]
[0]
23–5