ADEMCO VISTA-32FB Installation And Setup Manual page 140

Fire and burglary partitioned security system with scheduling
Table of Contents

Advertisement

VISTA-32FB Installation and Set-Up Guide
Auto arming can be delayed three ways: by use of the auto arm delay, the auto arm
warning, or by manually extending the closing (arming) time window with a keypad
command.
The system can also automatically bypass any open zones when auto arming.
Auto-Arm Delay
Auto-arm delay provides a delay (grace period) before auto arming.
It starts at the end of the closing time window.
The delay is set in 4-minute increments, up to 56 minutes in partition-specific program
field 2 05.
At the expiration of this delay, the auto-arm warning will start.
Auto-Arm Warning
The auto-arm warning causes the keypad sounder to warn the user of an impending
auto-arm.
The warning can be set from 1 to 15 minutes prior to the arming in partition-specific
program field 2 06.
During this period the keypad beeps every 15 seconds and displays AUTO ARM ALERT.
During the last 60 seconds, the keypads begin to beep every 5 seconds.
The panel arms at the conclusion of the auto-arm warning period.
Extend Closing Window
A user can manually delay the arm (closing) time window by 1 or 2 hours.
This is done by entering a keypad command ([User Code] + [#] + [82]), which then
prompts the user to enter the desired extension time of 1 or 2.
This feature is useful if a user must stay on the premises later than usual.
The auto-arm delay and warning periods will begin at the end of the extension.
Force Arm
The force arm option causes the panel to attempt to bypass any faulted zones prior to
auto-arming (panel will perform a force-arm).
This option is set in partition-specific program field 2 08.
Auto Disarming
The system can automatically disarm a partition at the end of a pre-determined opening
(disarm) time window.
The disarming time can be delayed by using the auto-disarm delay feature.
Disarm Delay
Auto-disarm delay provides a delay before auto disarming. This delay is added to the end
of the disarm time window.
The delay is set in 4-minute increments, up to 56 minutes, in partition-specific program
field 2 07.
Restrict Disarming
This option allows disarming by users only during the disarm time window and during
the arming time window (in case user needs to re-enter premises after manually arming
the partition).
This option is set in partition-specific field 2 10.
24–2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents