VISTA-32FB Installation and Set-Up Guide
•
When the 4100APG is to be mounted outside the cabinet, use the screw holes at the rear
to mount horizontally or vertically (2-faced adhesive tape may be used, if preferred). The
wires can be brought out from the side or back of the cabinet (a round breakout is also
available on the back).
Wiring the 4100APG
Without the Event Log Printer
The 4100APG connects to the VISTA-32FB via the 4100SM. The 4100SM is wired to the J2
connector on the control via the 4142TR Cable. See Figure 18-1.
Connecting the 4100SM to the control
1. Connect the 4142TR to J2 on the control.
2. Connect the RED wire of 4142TR to TB1-6 of 4100SM (RxD).
3. Connect the VIOLET wire of 4142TR to TB1-1 of 4100SM (DTR).
4. Connect the TB1-7 of 4100SM to terminal 12 (Auxiliary Power -) of the control.
5. Connect the TB1-8 of 4100SM to terminal 11 (Auxiliary Power +) of the control.
Connecting the 4100APG to the 4100SM
1. Connect the incoming telephone line to the 4100APG RJ11 connector labeled LINE.
2. Connect the (optional) handset side of telephone line to 4100APG RJ11 connector labeled
PHONE.
3. Connect the DB25M to DB-9M Cable (supplied), from 4100SM (25 pin) to 4100APG (9
pin) connector labeled SERIAL PORT INPUT.
18–2
J2
11 12
Aux. Pwr
Red
Aux. Gnd
Black
RxD
DTR
Figure 18-1: Wiring the 4100APG Without the Serial Printer
4100SM
8
7
6
5
4
3
2
1
DB-25
DB-9
Serial Port Input
RJ-11
Line
4100APG
To Telco