VISTA-32FB Installation and Set-Up Guide
Level 0: Installer (User 1) Codes
•
Programmed in field 00 (default = 5-1-4-0). Installer Open/Close reporting is selected
in field 39.
•
Can perform all system functions (arm, disarm, bypass, etc.), but cannot disarm if
armed by another code (or by Quick Arm).
•
Can add, delete, or change codes of all other authority levels, and can select Open/Close
reports for any user.
•
Is the only code that can be used to enter Program Mode. The Installer Code can be
prevented from re-entering the Program Mode by exiting using ∗98. The only way to
access Programming Mode if this done is by powering down the system, powering up
again, and then pressing both the [ ] and [#] keys at the same time within 30 seconds of
power-up.)
•
Must program at least one Master Code during initial installation. Master Codes are
intended for use by the primary user(s) of the system.
Level 1: Master Codes
•
Can perform all normal system functions.
•
Can be used to assign up to 73 lower-level codes, which can be used by other users of the
system.
•
Cannot assign anybody a level of 0 or 1.
•
May change personal code.
•
Can add, delete, or change Manager or Operator Codes. Each user's code can be
individually eliminated or changed at any time.
•
Open/Close reporting of added users is the same as that of the Master who is adding the
new user.
Level 2: Manager Codes
•
Can perform all system functions (arm, disarm, bypass, etc.) programmed by Master.
•
May add, delete, or change other users of the system below this level (Manager cannot
assign anybody a level of 0, 1, or 2).
•
May change personal code.
•
Open/Close reporting of added users is the same as that of the Manager who is adding
the new user.
Levels 3-5: Operator Codes
•
Can arm and disarm the system to the authority assigned, but cannot add or modify any
user code.
•
May operate a partition with one of the three Operator authority levels A through C in
the table below.
28–2
Auth
Title
0
Installer
1
Master
2
Manager
3
Operator level A
4
Operator level B
5
Operator level C
6
Duress