To load communication defaults, do the following:
Enter Program Mode [Installer Code] + [8 0 0]. Once the Programming Mode is entered,
first press 94 and then enter one of the following field numbers:
Loading communication defaults results in the following:
Low Speed
Selects low speed, standard format, with no checksum, for both phone numbers.
Assigns the following report codes:
( 94 80)
03 for zones 003-032
01 for zones 001, 002
02 for zones 995, 996, 999 (keypad panics)
09 for all alarm restores
Enables all zone type restores.
For expanded reporting, enable fields 52 and 53.
ADEMCO
Selects ADEMCO Express reporting format, with checksum, for both phone numbers.
Express
Report codes for zones 001-032, RF receiver, and keypad panics are sent as their
( 94 81)
respective zone ID numbers. Duress is sent as DD. Alarm restore is E + 2nd digit.
Enables all zone type restores.
ADEMCO
Selects ADEMCO High-Speed format with no checksum, for both phone numbers.
High-
Zone reporting is assigned to channels as described later in this section.
Speed
Enables all zone type restores.
( 94 82)
Enables duress to be sent.
ADEMCO's
Selects Contact ID format for both phone numbers.
Contact
Reporting is enabled for all zones.
ID
Enables all zone type restores.
( 94 83)
Refer to the Table of Contact ID Event Codes to follow.
TABLE OF DEFAULT PROGRAMMING COMMANDS
PRESS
TO LOAD THIS DEFAULT PROGRAM SET
Low Speed communication defaults
80
ADEMCO 4 + 2 Express communication defaults
81
ADEMCO High-Speed communication defaults
82
Contact ID communication defaults
83
Section 25 – System Communication
25–5