Optional Backup Dialer
Supports use of 5140DLM Backup Dialer for connecting to a second supervised telephone
line.
Optional Keyswitch
Supports the ADEMCO 4146 Keyswitch on any one of the system's 2 partitions. If used, zone
7 is no longer available as a protection zone.
Voltage Triggers
Provides a trigger connector whose pins change state for different conditions. Used with
LRR (Long Range Radio) equipment or other devices such as a remote keypad sounder,
keyswitch ARMED and READY LEDs, or a printer to print the system's event log.
Event Log
Keeps a log of different event types (enabled in programming). The event log has the
following characteristics:
•
Stores up to 224 events.
•
Can be viewed at the keypad or through the use of Compass software.
•
Can be printed on a serial printer using a 4100SM Module including zone alpha
descriptors.
•
Printed events can be sent to an alphanumeric pager.
Scheduling
Provides the following scheduling capabilities:
•
Open/close schedules (for control of arming/disarming and reporting).
•
Holiday schedules (allows different time windows for open/close schedules).
•
Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and
disarming, etc.).
•
Access schedules (for limiting system access to users by time).
•
End User Output Programming Mode (provides 20 timers for relay control).
Communications Formats
Supports the following formats for the primary and secondary central station receivers:
•
ADEMCO Low Speed (Standard or Expanded).
•
Sescoa/Radionics.
•
ADEMCO Express.
•
ADEMCO High Speed.
•
ADEMCO Contact ID.
•
Long Range Radio interface (ECP).
Audio Alarm Verification Option
Provides a programmable Audio Alarm Verification (AAV) option that can be used in
conjunction with an output relay to permit voice dialog between an operator at the central
station and a person at the premises. An optional AAV unit, such as Eagle Model 1250, is
required.
Section 1 – General Description
1–5