c. Arming the partition that is programmed to arm the lobby will cause the system to
automatically attempt to arm the lobby. If any faults exist in the lobby partition, or
another partition that affects the lobby is disarmed, the lobby cannot be armed, and the
message UNABLE TO ARM LOBBY PARTITION will be displayed.
You cannot select a partition to arm the lobby unless it has first been selected to affect the
lobby. Enable field 1 18 before enabling field 1 19.
The following chart sums up how the common lobby partition will operate if different options
are set for another partition in fields 1 18 and 1 19.
1 18
1 19
Affects Lobby
Arms Lobby
0
1
1
0
Example
Here is an example of how the lobby would react in a typical setup.
User #1 has access to Office #1 and the common lobby.
User #2 has access to Office #2 and the common lobby.
Office #1 is set up to affect the common lobby, but not arm it.
Office #2 is set up to affect and arm the common lobby.
Disarms when
partition
disarms?
0
NO
0
YES
1
YES
1
OFFICE #1
COMMON LOBBY
MAIN ENTRANCE
Section 2 – Planning a Partitioned System
Attempts to
Can be armed
arm when
if other
partition
partitions
arms?
disarmed?
NO
NO
YES
---ENTRY NOT ALLOWED---
OFFICE #2
YES
NO
NO
2–3