Section 22 - Zone Index/Zone Type Defaults; Zone Index - ADEMCO VISTA-32FB Installation And Setup Manual

Fire and burglary partitioned security system with scheduling
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section

Zone Index

Zone Type Defaults
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Zone Index
The VISTA-32FB has 32 protection zones, as well as supervisory zones for relays, ECP
devices (devices that communicate through the keypad terminals), and system troubles.
These zones are designated as follows:
ZONE # RANGE
001 - 032
601 - 616
800 - 830
900 - 990 and 997
991 - 999
Zone Index/Zone Type Defaults
ZONE FUNCTION
Protection zones
Relay Supervisory Zones
ECP Device Supervisory Zones
(includes keypads, wireless
receivers, VIP Module, relay
modules, etc.)
System Supervisory Zones
Keypad Panics
S E C T I O N
ACTUAL ZONE
As indicated
6 + 2-digit Relay Number; e.g.,
Relay Number 03, if supervised, is
zone 603.
8 + 2-digit Device Address; e.g.,
Device Address 01, if supervised, is
zone 801. The 4285/4286 VIP
Module is zone 804 (since its Device
Address must be set to 4).
970:
Bell Output 1
971:
Bell Output 2
972:
Earth Ground
973:
J2 Input 1 (LRR)
974:
Dialer 1
975:
Dialer 2
976:
Auxiliary Relay
977:
J2 LRR Trigger Outputs
988:
2nd Wireless Receiver -
not receiving signals
990: 1st Wireless Receiver -
not receiving signals
997:
Polling Loop (short circuit)
995:
1 +
panic (A key)
996:
3 + # panic (C key)
999:
+ # panic (B key)
2 2
22–1