Programming With #93 Menu Mode - ADEMCO VISTA-50P Quick Start Manual

Partitioned security system with scheduling, step-by-step programming procedure, single and multiple partition programming forms system worksheets
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

NOTE: The following fields should be preset before beginning: 2*00 Number of Partitions;
1*32 receiver type. In addition, receivers should be programmed via Device programming.
After programming all system related programming fields in the usual way, press #93 while still in programming
mode to display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to
the displayed menu selection. Pressing 0 will display the next choice in sequence. Menu selections are as follows:
ZONE PROG?
0=No
1=Yes
SERIAL PROG?
0=no
1=yes
ALPHA PROG?
0=no
1=yes
DEVICE PROG?
0=no
1=yes
RELAY PROG?
0=no
1=yes
RLY VOICE DESCR?
0=no
1=yes
CUSTOM INDEX #?
0=no
1=yes
#93 MENU MODE KEY COMMANDS
The following is a list of commands used while in the menu mode.
#93
Enters Menu mode
[ ]
Serves as ENTER key. Press to have keypadaccept entry.
[#]
Backs up to previous screen.
0
Press to answer NO
1
Press to answer YES
01-09
All data entries are 2-digit entries.
00
Escapes from menu mode, back into field programming mode.

PROGRAMMING WITH #93 MENU MODE

For programming the following:
• Zone Number
• Zone Response Type
• Hardwired zone
• RF Zone
• Right/left Loop Zone
• Serial number RPM zone
• Partition Number for Zone
• Dialer report code for zone
For entering (learning) 5800 transmitter & serial number polling loop device serial
numbers into the system.
For entering alpha descriptors for the following:
• Zone Descriptors
• Installer's Message
• Custom Words
• Partition Descriptors
• Relay Descriptors
For defining the following device characteristics for addressable devices, including
keypads, RF receivers (4281/5881), 4285 voice module and 4204 output relay modules:
• Device Address
• Device Type
• Device's Home Partition
• Keypad Options
• Voice Module
For defining output relay functions.
For entering relay voice descriptors to be used with voice module functions.
For creating custom word substitutes for voice module annunciation.
– 19 –

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-50pul

Table of Contents