General; Supervision; House Identification; Transm"Kter Identification - ADEMCO via30 Installation Instructions Manual

Table of Contents

Advertisement

EXPANSION
— 5700 RF SYSTEM —
General
Supervision
House Identification
Transmitter
Identification
5700 RF System
Installation
Advisories
I
1.
2.
3.
sary.
I
If the 4281 Receiver is to be
mounted remotely (not in the
control's cabinet), place it in
a high, centrally
located
area for best reception.
Do not locate receiver 01
transmitters
on or
neal
metal objects. This will de.
crease range and/or block
transmissions.
Before mounting transmit.
ters permanently, conduci
Go/No Go Tests to verif~
adequate
signal
strength
(see TESTING THE SYS
TEM) and reorient or relo
cate transmitters if neces
In addition to its basic 2 wired zones, the control, in conjunction with a 4281 RF
Receiver, can provide wireless zones [4281 L: up to 4 zones, 4281 M: up to 8,
4281 H (in this application): up to 30]. A wireless keypad (5727) also can be used
with the system.
The receiver can be mounted within the control's cabinet (see page 15) or in-
stalled remotely, in its own housing.
The 4281 recognizes alarms, status messages and keypad control messages
from 5700 Series Wkeless Transmitters operating at 345Mhz (315Mhz for Cana-
dian version). These messages are processed and relayed to the control panel
via a
4
wire connection to the control's remote console terminals. The 4281's
RED, BLACK, YELLOW, and GREEN wires are connected in parallel with console
wiring.
The 4281 can receive signals from wireless transmitters (listed below) within a
nominal range (installed) of 200 feet.
The 4281's DIP switch must be set for a device
address
of "O", as
described in the 4281's instructions (all switches to the RIGHT...''off").
Each transmitter (except 5701 and 5727) is supervised by a check-in signal that is
sent to the receiver at 70-90 minute intervals. If at least one check-in is not re-
ceived from each transmitter within a 12 hour period, the "missing" transmitter
number(s) and "CHECK" will be displayed on the console.
Each transmitter (including 5701) is also supervised for low battery conditions and
will transmit a low battery signal to the 4281, with the battery having at least 30
days of life remaining. If the 5727 transmits and has a low battery, it also will be in-
dicated (as Zone 00 on a fixed English console).
Note:
After a low or dead battery is replaced, activate the transmitter and then
enter the security code + OFF to clear the system's memory of the "Low
Battery" signal.
The 4281 itself is supervised. If communication with the receiver is interrupted, or
valid RF signals from at least one supervised wireless transmitter are not received
within 12 hours, a tamper report (Zone 9) will be generated.
The 4281 responds only to transmitters set to the same House ID (01-31, see the
DIP switch tables on page 46) as programmed in the control (see field *24). This
prevents interference from transmitters in other nearby systems. To make sure
that a House ID is chosen that is not in use nearby, conduct the Sniffer Mode test
described under TESTING THE SYSTEM.
Each transmitter's assigned zone number is DIP switch programmable in the unit
as its transmitter ID (except wireless keypads, which are fixed at ID 00). Whenever
a transmission takes place, whether for an alarm, fault, check-in, or low battery, the
ID number is sent along with the message to the 4281 which, in turn, relays this in-
formation to the control, which displays the condition and zone number on the
console.
WIRELESS TRANSMITTERS for the 4281 are described on page 41.
DIP SWITCH SETTING TABLES are shown on page 46.
Transmitters set for IDs of 48-55 (FIRE) have high signal priority and will
transmit once every 12 seconds while the zone is faulted.
Transmitter iDs of 62 and 63 are unsupervised to allow removal of the 5701
off-premises. Signal priority is higher than burglary.
Transmitters set for IDs of 56-63 will transmit once every 3 seconds while
faulted.
Transmitters set for IDs of 32-47 will have a 3 minute lock-out between
transmissions to conserve battery life (normally PIR units).
Note:
To conserve battery life, transmitters protecting frequent/y used doors
and windows should be set for IDs in the 32-47 range.
-9–

Advertisement

Table of Contents
loading