6. Other
6.7.2

Mounting of the Original Size Detecting Sensors (Option)

1. Remove the IR Upper Left Cover.
See P.50
2. Remove the Front Holding Bracket.
See P.50
3. Remove the Original Glass.
See P.50
4. Mount the Original Size Detecting Sensor (option).
5. Reinstall all parts which have been removed.
6. Select the functions as follows: Tech. Rep. Mode → [System Input] → [Original Size
Detecting Option]. Then, change the setting for Original Size Detecting Option from
[No] to [Yes].
7. Select the Tech. Rep. Mode → [Function] → [F7-1].
NOTE
• Select [F7-2] if the Fax Kit is mounted.
8. Stack five sheets of blank A3 paper on the Original Glass.
9. Press the Start key to perform automatic adjustment by the Original Size Detecting
Sensor
10. Turn OFF the Main Power Switch, wait for 10 sec., then turn the switch ON.
NOTE
• The Start key remains lit up orange while this function is being run and lights up
green as soon as the sequence is completed.
110