20. Image quality problem
20.3.2

Scanner System: Low image density or rough image

A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Shading Sheet
2
Mirrors/Lens/
Original Glass
3
Exposure Lamp
4
PWBs and Con-
nection Cables
5
MFBS Board
6
7
CCD Unit
8
272
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
Check Item
Shading sheet is dirty.
Mirrors, lens and/or Original Glass are
dirty.
Exposure Lamp is dirty.
Connectors are securely connected with
no bent pins and no breaks in the con-
nection cables.
Connectors on the MFBS Board are
connected properly.
The problem has been eliminated after
performing step 5.
Connectors on the CCD Unit Board are
connected properly.
The problem has been eliminated after
performing step 7.
Field Service Ver. 1.0 Dec. 2008
4036fs4036c0
Result
YES
Clean.
YES
Clean.
YES
Clean.
Change Exposure Lamp.
NO
Reconnect.
Replace the connection
cable.
NO
Reconnect.
NO
Change MFBS Board.
NO
Reconnect.
NO
Change CCD Unit.
Action