Replacement Of The Photo Conductor Unit And Developer - Konica Minolta bizhub 362 Service Manual

Field service
Hide thumbs Also See for bizhub 362:
Table of Contents

Advertisement

3. Periodical check
3.4.14

Replacement of the Photo Conductor Unit and Developer

1. Select Tech. Rep. Mode → [Counter] → [Special Parts Counter] → [PC Life].
2. Press the Clear key to clear the counter value.
3. Turn OFF the main power switch.
NOTE
• Clear the PC Life counter before removing the IU.
• After clearing the PC Life counter, be sure to turn OFF the main power switch.
• The Developer has to be replaced together with the Photo Conductor Unit
[3]
[2]
[6]
34
4. Open the Right Door.
[1]
5. Remove the IU [1].
4040F2C555DA
[2]
6. Remove four screws (silver) [2] and
disassemble the Photo Conductor
Unit [3] and the Developing Unit [4].
[4]
4040F2C556DA
7. Remove three screws [5] and the
Developer Scattering Prevention
Plate [6].
[5]
4040F2C579DA
8. Remove the Toner Supply Port [7].
[7]
4040F2C580DA