13.3 Settings In The Adjust Mode; Printer - Konica Minolta bizhub 362 Service Manual

Field service
Hide thumbs Also See for bizhub 362:
Table of Contents

Advertisement

13. Adjust Mode

13.3 Settings in the Adjust Mode

13.3.1

Printer

A. Registration (CD)
• To vary and adjust the image start position in the main scanning direction for each
Functions
paper source.
• The PH Unit has been replaced.
Use
• The image on the copy deviates in the main scan direction.
• A faint image occurs on the leading edge of the image.
Adjustment
Specifica-
tion
If width A on the test pattern is wider than specifications.
Adjustment
Longer than the actual scale: decrease the setting value.
Instructions
Shorter than the actual scale: increase the setting value.
1. Enter the Adjust Mode.
2. Touch [Printer] and [Registration (CD)] in that order.
3. Touch the [Test Print].
Setting/
4. Select the paper source and press the Start key.
Procedure
5. Check the dimension of width A on the test pattern.
6. If it fails to meet the specifications, change the setting and redo the check.
7. If it meets the specifications, touch [END].
8. Following the same procedure, adjust for all other paper sources.
218
Width A on the test pattern produced should fall
within the following range.
Specifications: 10 mm ± 2.0 mm
Setting Range: -4.0 mm to +4.0 mm
Width A
4040F3C517DA
Field Service Ver. 1.0 Dec. 2008
(in 0.1 mm increments)