Separation Claw - Konica Minolta bizhub 362 Service Manual

Field service
Hide thumbs Also See for bizhub 362:
Table of Contents

Advertisement

Field Service Ver. 1.0 Dec. 2008
[8]
[9]
[11]
6.3.43

Separation Claw

1. Remove the Fusing Unit.
See P.37
[1]
[2]
4. Remove two wiring saddles [6] and
the harness.
[6]
4040F2C730DA
5. Disconnect the connector [7] of the
Exit Sensor and remove the Exit
Rolls 2 Assy [8].
[7]
4040F2C431DA
6. Remove the screw [9] and the Sepa-
ration Claw Assy [10].
[10]
4040F2C644DA
7. Remove four Exit Rolls 2 [11].
4040F2C645DA
2. Snap off the C-clip [1] and remove
the Fusing Entrance Guide Plate [2].
4040F2C625DA
6. Other
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 282Bizhub 222

Table of Contents