6. Other
6.3.24

Manual Bypass Unit

1. Remove the Rear Right Cover.
See P.51
2. Remove the Lower Right Rear Cover.
See P.50
3. Remove the Front Manual Bypass Cover.
See P.56
4. Remove the Rear Manual Bypass Cover.
See P.56
[4]
[1]
[1]
[1]
6.3.25

PH Unit

1. Remove the Upper Rear Cover.
See P.51
2. Remove the Rear Cover.
See P.52
3. Open the Front Door.
4. Remove the Paper Output Cover.
See P.53
[1]
[2]
[1]
[4]
72
[3]
[2]
4040F2C574DB
[1]
4040F2C611DA
[3]
4040F2C612DA
Field Service Ver. 1.0 Dec. 2008
5. Remove five screws [1] and ground
wire [2], disconnect the three con-
nectors [3], and remove the Manual
Bypass Unit [4].
NOTE
• When the Manual Bypass Unit has
been mounted, be sure to perform
the Manual Bypass Unit Installation
Check procedures.
See P.230
5. Remove nine screws [1] and the PH
protective metal bracket [2].
6. Remove two screws [3] and the
Paper Output Tray Rear Cover [4].