Field Service Ver. 1.0 Dec. 2008
10. Set error detection
• When the ADF or cover set error for some reason is detected, the Panel of the main body
will have the following display.
[1]
<Panel display and detection timing for each>
Panel
Description of error
display
[1]
Upper Door closure
[2]
ADF closure
Detection start
When the document is
loaded into the ADF
When the document is
loaded into the ADF
10. Set error detection
[2]
Detection timing
Upper Door Open/Close Sensor
(unblocked)
Copier Size Reset Switch (ON)
4344F4E504DA