I. Outline of Installation Procedures for bizhub 362/ bizhub 282/ bizhub 222
PC-108
SP-501
MT-502
When installing the machine and associated options as a system, follow the order shown on the upper.
Note:
• For the detailed installation procedures for each option, follow the instructions given in the corresponding
Installation Manual and perform the procedures correctly.
• Once the power switch is turned ON, do not turn it OFF until the installation work has been completed.
• When transporting or moving the machines, assign adequate number of persons. (Machine mass: 74 kg/
169-1/2 lb)
/
INSTALLATION MANUAL
PC-206
Dehumidifier Heater 1C
Machine
DF-620
FS-530
PU-501
SD-507
OT-602
/
Applied Machine:
PC-407
DK-506*
OC-510
JS-502
EM-303/
EM-304/
EM-305
* Depending on the applicable marketing area.
E-1
/
/
MK-709*
SU-501
FK-503
ML-502
HD-504
SC-504
EK-502
A11UIXC006MA
A11U-9640-00

Advertisement

loading

Summary of Contents for Konica Minolta bizhub 362

  • Page 1 INSTALLATION MANUAL Applied Machine: I. Outline of Installation Procedures for bizhub 362/ bizhub 282/ bizhub 222 PC-108 PC-206 PC-407 DK-506* Dehumidifier Heater 1C Machine DF-620 OC-510 SP-501 FS-530 PU-501 JS-502 MK-709* MT-502 SD-507 EM-303/ SU-501 FK-503 EM-304/ EM-305 ML-502 OT-602...
  • Page 2: Accessory Parts

    II. Installation Space (unit: mm (inch)) IV. Accessory Parts bizhub 362 + PC-206 + SD-507 + DF-620 Name Q’ty 1. User’s Guide (Copy Operations)* 1757 (69-1/4) 2. User’s Guide (Box Operations)* (4-3/4) 1312 (51-3/4) (12-3/4) 3. User’s Guide (Network Scanner Operations)* 4.
  • Page 3 V. Removing Machine from Packaging Box VI. Removing Protective Tape and Packag- ing Materials and Unlocking Scanner 1. Unpack the packaging box and remove cushion- ing materials and plastic bags from the box. 1. Remove pieces of protective tape and packaging 2.
  • Page 4 VII. Loading the Starter 5. Slide out the drawer and remove the protective tape. 1. Open the right door and remove the imaging unit (IU). A11UIXC004MA 6. Slide the drawer back in. A11UIXC011MA 7. Remove the protective sheet. 2. Remove screws that secure the PC drum unit in position (two silver screws each on the right and left sides).
  • Page 5 5. Remove the toner supply port. 8. Ready a packet of starter and cut off one corner of the aluminum packet with scissors. A11UIXC014MA A11UIXC016MA 6. Remove the liner from the Mylar sheet included in the machine. 9. While turning the gear in the direction of the arrow, pour the packet of starter evenly into the developer chamber.
  • Page 6 11. Reinstall the toner supply port. 13. Align the shaft of the developing unit with the inner guide of the PC drum unit. Note: 14. Slide the PC drum unit along the guide to check Make sure of the correct mounting position and that the positioning pin is properly aligned with direction.
  • Page 7: Clearing The Counters

    IX. Plugging in Power Cord and Turning 5. Turn ON the sub switch located on the side of the control panel. Power ON 1. Plug in the power cord to the machine. A11UIXC023MA A11UIXC020MA X. Clearing the Counters 2. Connect the power cord to a power outlet. 1.
  • Page 8: Installing The Toner Bottle

    XI. ATDC Adjustment XII. Installing the Toner Bottle 1. Install the imaging unit (IU) in position. Note: The toner bottle is not shipped with the machine. 2. Close the right door. Purchase one that is separately available. 1. From a height of about 10 cm, tap the toner bottle against a table or other hard object four to five times.
  • Page 9 XIII. Affixing the Tray Label 4. Open the toner holder and mount the toner bottle. Note: 1. Affix the tray label to the 1st and 2nd drawers. Place the toner bottle so that the tape faces upward. 5. Close the toner holder. A11UIXC005MA 2.
  • Page 10: Date/Time Setting

    XV. Date/Time Setting XVI. Connecting Cables 1. Call the Initial Mode to the screen. (For the pro- 1. With the network cable (category 5), connect the cedure, see the Service Manual.) machine to the network device (hub). LED (Yellow) LED (Green) A11UIXC036MA A11UIXC034MA 2.
  • Page 11 XVIII. Setting the CSRC 7. Touch “Detail Setting.” 8. Touch “RAM Clear.” Note: This step may not be performed depending on the applicable marketing area. <When using the phone line modem> 1. Register the Device ID to the application at CS Remote Care Center.
  • Page 12 14.Touch “Detail Setting.” 20.Touch “Center ID.” 15.Touch “Date & Time Setting.” 21.Enter the Center ID (five digits) and touch “Enter.” 22.Touch “Center Phone No.” 23.Enter the Center Phone No. using the ten-key pad as well as P, T, W, and – keys on the screen, and touch “Enter.”...
  • Page 13 36.Touch “Initial Transmission” at the right bottom of <When using an e-mail> the screen to start initial transmission. 1. Register the Device ID to the application at CS Note: Remote Care Center. When the Device ID is not The Initial Transmission key at the right bottom of registered, initial connection will not be per- the screen will be displayed only when the Center formed.
  • Page 14 9. Touch “YES.” 16.Enter the date, time, and the time zone using the ten-key pad. 10.Touch “END.” 17.Touch “Job Start.” A11UIXC043MA A11UIXC044MA 11.“CS remote Care” → Select “E-Mail.” 18.Touch “END.” 12.Touch “ID Code.” 19.Touch “Basic.” 13.Enter the seven-digit ID using the ten-key pad, and touch “ID Code”...
  • Page 15 24.Touch “END.” 29.Touch “Server for RX.” 25.Touch “Respond Timeout.” 30.Set the POP3 server address, POP3 user name, POP3 password, and POP3 port number. 31.Touch “END.” A11UIXC049MA 26.Enter the responding time using the ten-key pad, A11UIXC053MA and touch “Enter.” Note: 32.Touch “RX Settings.” •...
  • Page 16 38.Touch “TX/RX Test”, and touch the Start key to perform transmission. Check whether transmis- sion is performed normally. When transmission fails, check according to the error message and try transmitting again. 39.Keep touching “END” until Tech. Rep. Mode is displayed. 40.Touch “Exit”...
  • Page 17 OC-510 Original Cover (Option) INSTALLATION MANUAL I. Installing the Original Cover Kit 4. Install the Original Cover. 5. Peel the double-sided adhesive tape off the docu- Name Q’ty ment scanning glass cover. Then, affix the docu- ment scanning glass cover to the position shown 1.
  • Page 19: Manuel D'installation

    MANUEL D'INSTALLATION Machine concernée: I. Description générale des procédures d'installation PC-108 PC-206 PC-407 DK-506* Déshumidificateur réchauffeur 1C Machine OC-510 SP-501 DF-620 FS-530 PU-501 JS-502 MK-709* SU-501 FK-503 MT-502 SD-507 EM-303/ EM-304/ EM-305 ML-502 OT-602 HD-504 SC-504 EK-502 * Varie suivant la région de vente applicable. Lors de l'installation de la machine et des options associées en tant que système, se conformer à...
  • Page 20 II. Espace d'installation (unité: mm IV. Pièces accessoires (pouce)) N° Dénomination Qté bizhub 362 + PC-206 + SD-507 + DF-620 1. Guide utilisateur (Opérations de copie)* 1757 (69-1/4) 2. Guide utilisateur (4-3/4) 1312 (51-3/4) (12-3/4) (Opérations de boîte)* 3. Guide utilisateur (Opérations de scanneur réseau)*...
  • Page 21 V. Extraction de la machine de son VI. Retirer la bande de protection et carton d'emballage les matériaux d'emballage puis déver- rouiller le scanneur 1. Vider le carton d'emballage et retirer les matériaux de bourrage et les pochettes en vinyle du carton. 1.
  • Page 22 5. Dégager le tiroir et retirer la bande de protection. VII.Chargement du bloc d'amorçage 1. Ouvrir la porte droite et retirer l'unité de formation d'image (IU). A11UIXC004MA 6. Remettre le tiroir en place. A11UIXC011MA 7. Retirer la feuille de protection. 2.
  • Page 23 4. Retirer le couvercle de l'unité de développement (trois 7. Fixer les feuilles de mylar (deux emplacements). vis de fixation). Remarque: S'assurer que le collet est complètement recouvert par la feuille de mylar. Collet A11UIXC013MA 5. Retirer le port d'alimentation de poudre révélatrice électrostatique.
  • Page 24 9. Tout en faisant tourner l'engrenage dans la direction 12. Remonter le couvercle de l'unité de développement indiquée par la flèche, verser uniformément le con- couvercle et s'assurer que ses languettes sont parfait- tenu de la pochette de produit d'amorçage dans la ement engagées correctement dans les fentes (trois chambre de révélateur.
  • Page 25 VIII. Raccordement du câble de IX. Raccordement du cordon d'ali- modem CSRC mentation et mise sous tension 1. Brancher le cordon d'alimentation dans la machine. Remarque: • Cette étape peut éventuellement ne pas être exécutée selon la région de vente applicable. •...
  • Page 26 5. Appliquer l'alimentation avec l'interrupteur d'alimen- XI. Réglage ATDC tation secondaire situé sur le panneau de commande. 1. Mettre l'unité de formation d'image (IU) en place. 2. Fermer la porte droite. A11UIXC023MA A11UIXC025MA X. Remise à zéro des compteurs 3. Sélectionner les fonctions dans cet ordre: Tech. Rep. Mode →...
  • Page 27 3. Ouvrir la porte avant et faire coulisser la trémie d'ali- XII. Installation du flacon de poudre mentation de poudre révélatrice électrostatique hors de révélatrice électrostatique la machine. Remarque: Le flacon de poudre révélatrice électrostatique n'est pas expédié avec la machine. Faire l'achat d'un flacon en vente séparément.
  • Page 28 6. Décoller délicatement l'adhésif d'étanchéité du flacon XIII. Fixation de l'étiquette de plateau en agissant vers soi. 1. Coller l'étiquette de plateau sur les 1er et 2ème tiroirs. Remarque: Exécuter cette procédure lentement car la poudre révél- atrice électrostatique risque de jaillir soudainement hors du flacon au moment où...
  • Page 29: Raccordement Des Câbles

    XV. Réglage de la date ou de l'heure XVI. Raccordement des câbles 1. Rappeler Initial Mode à l'écran. (Se référer au manuel 1. En utilisant le câble de réseau (catégorie 5), réaliser le de révisions en ce qui concerne la procédure.) branchement des câbles entre le périphérique de réseau (centre nodal) et la machine.
  • Page 30 5. Toucher “ID Code.” XVII. Paramétrage de réseau 6. Saisir l'identification à sept chiffres en utilisant le cla- Faire le paramétrage de l'adresse TCP/IP pour le réseau. vier à dix touches, puis toucher encore une fois “ID Remarque: Code.” Consulter l'administrateur de réseau en ce qui concerne la valeur de paramétrage à...
  • Page 31 13. Saisir l'identification à sept chiffres en utilisant le cla- 19. Toucher “Basic.” vier à dix touches, puis toucher encore une fois “ID Code.” A11UIXC042MA 20. Toucher “Center ID.” A11UIXC041MA 21. Saisir Center ID (cinq chiffres) et toucher “Enter.” 14. Toucher “Detail Setting.” 22.
  • Page 32 29. Toucher “END.” <Lorsqu'une adresse email est utilisée> Suivre la procédure 30 jusqu'à 34 uniquement pour 1. Enregistrer l'identification d'appareil dans le pro- une communication PHS. gramme d'application au centre de télé-assistance CS 30. Toucher “Software Switch Setting.” Remote Care Center. Lorsque l'identification d'appar- eil n'est pas enregistrée, la connexion initiale ne sera 31.
  • Page 33 9. Toucher “YES.” 16. Saisir la date, l'heure et le fuseau horaire en utilisant le clavier à dix touches. 10. Toucher “END.” 17. Toucher “Job Start.” A11UIXC043MA A11UIXC044MA 11. Toucher “CS Remote Care” → sélectionner “E- Mail.” 18. Toucher “END.” 12.
  • Page 34 24. Toucher “END.” 29. Toucher “Server for RX.” 25. Toucher “Respond Timeout.” 30. Paramétrer POP3 Server Address, POP3 User Name, POP3 Password, et POP3 Port Number. 31. Toucher “END.” A11UIXC049MA 26. Saisir le temps de réponse en utilisant le clavier à dix A11UIXC053MA touches et toucher “Enter.”...
  • Page 35 38. Toucher “TX/RX Test” et toucher la touche Start pour exécuter la transmission. Vérifier que la trans- mission se déroule normalement. Lorsque la trans- mission échoue, vérifier en fonction du message d'erreur et refaire une tentative de transmission. 39. Continuer à toucher “END” jusqu'à ce que l'écran Tech.
  • Page 36 OC-510 Original Cover (Option) MANUEL D'INSTALLATION 2. Installer les couvercles à charnière (droit et gauche) y I. Installation de l'ensemble de compris l'ensemble (cinq vis de fixation). couvercle d'origine 3. Remonter le couvercle arrière supérieur (trois vis de fixation). Quan- tité...

This manual is also suitable for:

Bizhub 222Bizhub 282