Konica Minolta bizhub 362 Service Manual page 581

Field service
Hide thumbs Also See for bizhub 362:
Table of Contents

Advertisement

12. Troubleshooting
Error
Error Details
Code
9A
Correct line cannot be
decoded within 35
seconds during ECM
image signal recep-
tion
9C
CRP is received thrice
during waiting for
answer for initial rec-
ognition signal
9D
Reception command
error (not carrier dis-
connection)
9F
Pages being received
by EOR-Q or EOR-
PRI-Q signals from
the transmission side
with ECM procedure
are destroyed (since
the procedure is con-
tinued, the next page
may be transmitted)
194
Possible Cause
Dest. Line Self
V.34 failure
Destination
machine failure
Line failure
(packet loss,
delay, etc.)
FAX(S) board
failure
MFBS board fail-
ure
V.34 failure
Destination
machine failure
Line failure
(packet loss,
delay, etc.)
FAX(S) board
failure
MFBS board fail-
ure
V.34 failure
Destination
machine failure
Line failure
(packet loss,
delay, etc.)
V.34 failure
Destination
machine failure
Line failure
(packet loss,
delay, etc.)
Field Service Ver. 1.0 Dec. 2008
Action to be Taken
Set V.34 to OFF and the signal
transmission level to -16dBm, and
send again.
Change the destination machine
and send again.
Confirm the status of the network
(HUB connection, etc.)
Replace FAX(S) board.
Replace MFBS board.
Set V.34 to OFF and the signal
transmission level to -16dBm, and
send again.
Change the destination machine
and send again.
Confirm the status of the network
(HUB connection, etc.)
Replace FAX(S) board.
Replace MFBS board.
Set V.34 to OFF and the signal
transmission level to -16dBm, and
send again.
Confirm the status of the destina-
tion machine.
Confirm the status of the network
(HUB connection, etc.)
Set V.34 to OFF and the signal
transmission level to -16dBm, and
send again.
Confirm the status of the destina-
tion machine.
Confirm the status of the network
(HUB connection, etc.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 282Bizhub 222

Table of Contents