19. Power supply trouble

19.1 Machine is not Energized at All (PU1 Operation Check)

Main Power Switch (S1)
Power Supply Unit (PU1)
Step
Is a voltage being applied to the electrical
1
outlet?
2
Is the wiring to terminal S1 correct?
Is there continuity across the fuse (F101)
3
on PU1?
Is there continuity across the fuse (F103)
4
on PU1?
Is the wiring between the MFBS Board and
5
Mechanical Control Board correct?
Is the wiring between the Mechanical Con-
6
trol Board and Power Supply Unit correct?
Is DC 5 V being output from PJ8A-2 on the
7
PWB-A?

19.2 Only the Power Supply Cooling Fan Motor turns

Power Supply Unit (PU1)
Control Panel (UN1)
Step
Is DC 4.5 V being output from PJ8A-3 on
1
the PWB-A?
Is DC 5 V being output from PJ9PU1-1 on
2
PU1?
Relevant Electrical Parts
Check Item
Relevant Electrical Parts
Check Item
19. Power supply trouble
Mechanical Control Board (PWB-A)
MFBS Board (MFBS)
Location
(Electrical
Result
Component)
-
NO
Provide a power supply.
W-22
NO
Rewire
-
NO
Change the fuse.
-
NO
Change the fuse.
-
NO
Rewire
-
NO
Rewire
NO
Change PWB-A
-
YES
Change PU1
Mechanical Control Board (PWB-A)
Location
(Electrical
Result
Component)
-
NO
Change PWB-A
NO
Change PU1
-
YES
Change UN1
Action
Action
267