3. Other
3.3.2

Main Control Board

[2]
NOTE
• Be sure to perform the following operation when the Main Control Board is
replaced.
5. Initialize the backup data.
See P.21
6. Perform document width detection adjustment.
See P.18
7. Turn OFF the Main Power Switch and turn it ON again and check whether size detec-
tion operates normally.
8. Upgrade the firmware.
See P.16
3.3.3

Variable Resistor

[2]
[3]
[7]
12
[1]
[1]
4344F2C514DA
[1]
[2]
4344F2C522DA
[4]
4344F2C523DA
[5]
[6]
4344F2C524DA
Field Service Ver. 1.0 Dec. 2008
1. Turn OFF the Main Power Switch.
2. Remove the Rear Cover.
See P.11
3. Disconnect all the connectors on the
board.
4. Remove three screws [1], and then
remove the Main Control Board [2].
A. Removal Procedure
1. Turn OFF the Main Power Switch.
2. Remove the Original Feed Tray Rear
Cover.
See P.11
3. Disconnect the connector [1].
4. Remove two screws [2] and the
mounting bracket [3].
5. Remove the gear [4].
6. Remove the nut [5] and the washer
[6], and remove the Variable Resistor
[7].