18. Malfunction code
18.3.25
C5351: Power Supply Cooling Fan Motor Failure
Power Supply Cooling Fan Motor (M4)
Step
Check the M4 connectors for proper connection,
1
and correct as necessary.
Check the fan for possible overload, and correct as
2
necessary.
3
M4 operation check
4
Change PU1
18.3.26
C5352: Cooling Fan Motor Failure
Cooling Fan Motor (M5)
Step
Check the M5 connectors for proper connection,
1
and correct as necessary.
Check the fan for possible overload, and correct as
2
necessary.
3
M5 operation check
4
Change PWB-A
18.3.27
C5353: IU Cooling Fan Motor Failure
IU Cooling Fan Motor (M6)
Step
Check the M6 connectors for proper connection,
1
and correct as necessary.
Check the fan for possible overload, and correct as
2
necessary.
3
M6 operation check
4
Change PWB-A
264
Relevant Electrical Parts
Power Supply Unit (PU1)
Action
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
Field Service Ver. 1.0 Dec. 2008
WIRING DIAGRAM
Control Signal
-
-
PWB-A PJ33A-1 (REM)
-
WIRING DIAGRAM
Control Signal
-
-
PWB-A PJ11A-6 (REM)
-
WIRING DIAGRAM
Control Signal
-
-
PWB-A PJ15A-1 (REM)
-
Location
(Electrical
Component)
-
-
D-5
-
Location
(Electrical
Component)
-
-
M-8
-
Location
(Electrical
Component)
-
-
D-16
-