Field Service Ver. 1.0 Dec. 2008
MODE
093 (PSTN1)
123 (PSTN2)
Bit
Feature
7
Select timing for starting
CED sending.
6
5
Select CED frequency.
4
3
Process CED echo.
2
Process incoming com-
mand echo.
1
Control channel data rate. Bit 1-0:
0
MODE
094 (PSTN1)
124 (PSTN2)
Bit
Feature
3
Lock AGC in V.33 mode.
2
Lock AGC in V.17 mode.
1
Lock AGC in V.29 mode.
0
Lock AGC in V.27ter
mode.
Factory setting bit
Bit:
7 6 5 4
0 1 0 0
Logic
0
Bit 7-6:
00
01
10
11
Bit 5-4:
00
01
10
11
No
Yes
No
Yes
00
01
10
11
Factory setting bit
Bit:
7 6 5 4
0 0 0 0
Logic
0
No
Yes
No
Yes
No
Yes
No
Yes
11. Soft Switch Settings
HEX:48 (For U.S.)
HEX:40 (For Europe)
3 2 1 0
1 0 0 0
HEX:48 (For U.S.)
HEX:48 (For Europe)
Description
1
0 msec
Specifies time interval
from line connection to
2000 msec
starting sending CED.
2500 msec
(7-sec is provided for the
7 sec
second dial.)
2100 Hz
Specifies frequency to
carry CED or N/A selec-
1080 Hz
tion.
1300 Hz
Not available
Specifies whether to process CED echo
at the intervals of 500 ms between CED
and initial identification.
Specifies whether to process incoming
echo at the intervals of 500 ms between
when receiving an initial identification
and when sending the incoming com-
mand.
1200 bps
Non 1200 bps
2400 bps
Non 2400 bps
3 2 1 0
HEX:0C
1 1 0 0
Description
1
91