Field Service Ver. 1.0 Dec. 2008
6.4

Cleaning procedure

NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
6.4.1

Manual Bypass Feed Roller

1. Remove the Manual Bypass Unit.
See P.72
[1]
[3]
6.4.2

Manual Bypass Separation Roller

1. Remove the Manual Bypass Unit.
See P.72
[1]
[3]
[2]
4037F2C515DA
4037F2C516DA
[2]
4037F2C515DA
4037F2C521DA
2. Remove two screws [1] and the Man-
ual Bypass Separation Fixing
Bracket Assy [2].
3. Using a soft cloth dampened with
alcohol, wipe the Manual Bypass
Feed Roller [3] clean of dirt.
2. Remove two screws [1] and the Man-
ual Bypass Separation Fixing
Bracket Assy [2].
3. Using a soft cloth dampened with
alcohol, wipe the Manual Bypass
Separation Roller [3] clean of dirt.